NCL AAC BLOCKS

prod specs Image
prod Image
PRODUCT DESCRIPTION

The light weight NCL AAC BRICKS are made of light weight fillers, cement, fine additives, lime etc.
through chemical reaction which creates constant cellular structure and cures in autoclave under
high pressure stream which strengthens the bricks.

prod Image
ADVANTAGES
  • Best suitable alternative for Clay Bricks / Hollow / Solid Concrete Blocks
  • Light weight bricks reduce the dead load on structure
  • Speedy work
  • Dimensional accuracy
  • Can be cut into any size / shape easily
  • Very good mechanical strengths
  • Energy efficiency
  • Fire-resistant
  • Sound insulation
  • No fungal growth
  • Better wall surface level
  • No VOC
  • Eco-friendly
  • Conforms to IS 2185
prod Image
SAVINGS ON OVERALL PROJECT COST
  • On jointing and plastering mortars
  • On steel by 20-25% and concrete by 10%
  • On labor and transportation cost
  • On project implementation time
prod Image
Workability:
  • Easy to lay
  • Can be cut in to any size/shape
prod Image
INSULATION
  • Superior thermal insulation that reduces load on air-conditioner
  • Superior sound insulation with a STC rating of 44
prod Image
PACKING PLACE = SIZES AVAILABLE
Length Height Thicknesses
600 mm 200 mm 100/150/200/225 mm
prod Image
APPLICATION AREAS
  • Internal & External wall constructions for normal & multi-storeyed buildings
  • Individual houses
  • Highrise apartments
  • Partition walls
  • For fast constructions
Sl. No. Attributes Standard NCL Block Conforms
1 Moisture Mfg. Spec < 22%
2 Dry Density IS 2185 550 - 650 kg/m3
3 Compressive Strength IS 2185 > 4.0 Mpa
4 Sound Reduction Index - W/O Plastering NA 38 db
5 Fire Resistance IS 3809 4 - 6 Hr
6 Thermal Conductivity IS 2185 0.16 w/m.k
7 Dry Shrinkage IS 2185 0.07%
8 Dimensional Accuracy NA +/- 1 mm

Installation: Before application – wet the brick. For better performance use self curing block / Brick mortar with 3 to 4 mm thickness and apply the same with notching trowel. Apply a thin layer of block mortar in the thickness of 3 to 4 mm on the clean and leveled surface using proper trowel on which the block work is to be carried out. Place the block on the laid block mortar in proper line and level. After placing the first block apply the jointing mortar of the same thickness i.e. 3-4 mm on both horizontal and vertical joint of the block then place the AAC bricks. The lentil should be placed for every 5 to 6 layers of AAC Blocks or 6 m length to avoid cracks. It should be placed on a complete block. Use a tool like hacksaw or rotary cutter to cut into required size & shape. Curing is not required.

DO'S
  1. The level from base to the top layer should be properly horizontal
  2. There should not be any gap between the joints of AAC Blocks
  3. Bottom layer of AAC Block should be properly laid, so that no gaps should come in between otherwise the blocks would crack
  4. The lentil should be placed after every 5 to 6 layers of AAC Blocks or 6 m length to avoid cracks. It should be placed on a complete block
  5. Storage on dry and even surface to avoid damage and contact with moisture
  6. Before application – wet the block
  7. Use self curing block mortar with 3 to 4 mm thickness only and notching is mandatory
  8. Use a tool like hacksaw or rotary cutter
  9. Should rest on full block
DON'TS
  1. Do not use a rich mortar mix as it tends to shrink & might crack
  2. Do not flood the brick with water
  3. Do not construct a wall without coping the beam
  4. Do not stack the blocks in haphazard manner or leave them exposed to rain or moisture
  5. Do not use tools like hammer, chisel etc. to cut the block
Marketed by:
NCL Buildtek Ltd.,
10-3-162, 5th Floor, NCL Pearl,
SD Road, East Maredpally,
Secunderabad - 500 026.
Ph: +91 40 6831 3333
e-mail: contactus@nclbuildtek.com
Website: www.nclbuildtek.com